General Specification
Use 3-wire, 4-20 mA, gas detector transmitter for use with directly installed flammable and toxic gas sensors. For the protection of personnel and plant from flammable and toxic gas hazards.HONGKONG XIEYUAN TECH CO., LIMITED ava.wong@hkxytech.com Mob/WhatsApp: 86-15602323637SPXCDALMO1M Honeywell Sensepoint XCD Gas Detector
General Specification
- Use
3-wire, 4-20 mA, gas detector transmitter for use with directly installed flammable and toxic gas sensors. For the
protection of personnel and plant from flammable and toxic gas hazards. - Electrical
Input Voltage Range: 16 to 32 Vdc (24 Vdc nominal) for ATEX/IECEx/AP Versions
12 to 32 Vdc (24 Vdc nominal) for UL/CSA version
Max Power Consumption: Max 5 Watts. at 24 Vdc (see chapter 2 regarding maximum in rush
current) Current output 4-20 mA (Source or Sink)
≥0.0<1.0 mA Fault (refer to table 5 chapter 11.3 for further details).
4.0 mA to 20.0 mA Normal gas measurement
2.0 mA or 4.0 mA (17.4 mA) Inhibit (during configuration/user settings)
22.0 mA Maximum over range
Max load resistance 250 Ω
Terminals 15 x screw terminals suitable for wire diameter 0.5 mm2 to 2.5 mm2 (20 AWG
to 13 AWG).
Relays 3 x 5 A@250 VAC. Selectable normally open or normally closed (switch) and
energized/de-energized (programmable).
Communication RS485, Modbus RTU - Construction
Material Epoxy painted aluminium alloy or 316 Stainless Steel
Weight Aluminum alloy: 1.7 kg, 316 Stainless Steel: 3.7 kg
Mounting: Pole or wall mounting
Entries 2 x M20 (for ATEX/IECEx/AP Approval) or 2×3/4’ NPT (for UL Approval) - Environmental
IP Rating: IP66 in accordance with EN60529:1992
Operating Temperature: -40ºC to +75ºC/ -40ºF to +167ºF
Note: The detector display may become illegible at temperatures below -40°C, but the detector continues its gas
monitoring function. The display is not damaged and recovers when the temperature rises back above -20 °C.
Operating Humidity: Continuous 20-90 % RH (non-condensing), Intermittent 10-99 % RH (non-condensing)
Operating Pressure: 90-110 kPa (EC Toxic Sensors), 80-120 kPa (EC Oxygen, Catalytic Bead and Infrared Sensors)
Storage Conditions (detector and accessories): -25°C to +65°C (-13°F to +149°F)